How to enable or disable the MORE prompt
I’ve had setup on one of the routers (R2) to show running-config without any –more– prompts. At any given time I couldn’t see the previous lines. So this configuration is not a good one.
This is how to enable the –more– prompt:
terminal length 30
(or any number between 1 and 512, 24 is the default)
and verify:
R2#show terminal Line 0, Location: "", Type: "" Length: 30 lines, Width: 80 columns Baud rate (TX/RX) is 9600/9600, no parity, 2 stopbits, 8 databits Status: PSI Enabled, Ready, Active, Automore On Capabilities: none Modem state: Ready
This is how to disable the –more– prompt:
terminal length 0
and verify:
R2#show terminal Line 0, Location: "", Type: "" Length: 0 lines, Width: 80 columns Baud rate (TX/RX) is 9600/9600, no parity, 2 stopbits, 8 databits Status: PSI Enabled, Ready, Active, Automore On Capabilities: none Modem state: Ready